BOCK HGX12/30-4 SH CO2 T
HG CO2 T
German semi-hermetic compressors for transport refrigeration, heat pumps, and bus air-conditioning.


Specifications
- Compression technology: Reciprocating
- Configuration: Transcritical
- Enclosure / drive: Semi-Hermetic
- Cylinders: 2
- Variable speed: Fixed-Speed
- Hazardous-area certification: No
- Product category: compressor
Qualified refrigerants & capacity
Calculated cooling capacity (kW). The evaporating / condensing temperature each column was evaluated at is listed per refrigerant, because the grid differs by refrigerant.
| Refrigerant | ULT | LT | MT | HT | Conditions |
|---|---|---|---|---|---|
| R744 | — | — | — | — | ULT -40 / -10 °C; LT -30 / -5 °C; MT -5 / 25 °C; HT -5 °C evaporating, transcritical gas cooler |
Related BOCK models
- EX-HG12P/110-4
- EX-HG12P/110-4 HC
- EX-HG12P/110-4 S
- EX-HG12P/110-4 S HC
- EX-HG12P/60-4 S
- EX-HG12P/60-4 S HC
- EX-HG12P/75-4
- EX-HG12P/75-4 HC
Frequently asked questions
What refrigerants does the BOCK HGX12/30-4 SH CO2 T support?
The BOCK HGX12/30-4 SH CO2 T is qualified for R744. The table above lists capacity at ultra-low, low, medium and high temperature duty for each refrigerant, with the evaporating and condensing temperature each value was calculated at. Those conditions differ by refrigerant, so read them per row.
What type of compressor is the BOCK HGX12/30-4 SH CO2 T?
DigiEntropy classifies the BOCK HGX12/30-4 SH CO2 T as HG CO2 T. Browse the BOCK catalog to compare nearby models from the same brand.
Can the BOCK HGX12/30-4 SH CO2 T be retrofit to a lower-GWP refrigerant under EU F-Gas Regulation 2024/573?
Open the F-Gas Retrofit tool with this model pre-selected to see drop-in alternatives ranked by capacity match, COP, GWP, PFAS impact, and 2026/2030/2035 phase-out timeline.
Where does the BOCK HGX12/30-4 SH CO2 T performance data come from?
From BOCK's own published performance data, evaluated at the suction and liquid conditions the manufacturer declares with it. Which rating standard the manufacturer certifies to (EN 12900 or AHRI 540) is not stated on this page; check the manufacturer's datasheet. Fit your own data in the Polynomial Fitter tool.