BOCK HGX34e/315-4

FM_HG

German semi-hermetic compressors for transport refrigeration, heat pumps, and bus air-conditioning.

BOCK logo

Specifications

  • Compression technology: Reciprocating
  • Configuration: Single
  • Enclosure / drive: Semi-Hermetic
  • Variable speed: Not Stated
  • Hazardous-area certification: Not Stated
  • Product category: compressor

Qualified refrigerants & capacity

Capacity (kW) evaluated at standard conditions: ULT (-60/45 °C), LT (-35/45 °C), MT (-10/45 °C), HT (-5/45 °C).

RefrigerantULTLTMTHT
R134a7.569.79
R223.4113.3316.41
R404A3.3613.2116.14
R407A2.3612.1715.42
R407C11.0413.87
R407F12.7916.01
R448A2.5412.515.77
R449A2.5312.4215.67
R450A6.548.48
R452A3.0313.0316.07
R513A8.0210.24

Related BOCK models

Frequently asked questions

What refrigerants does the BOCK HGX34e/315-4 support?

The BOCK HGX34e/315-4 is qualified for R134a, R22, R404A, R407A, R407C, R407F, R448A, R449A, R450A, R452A, R513A. Capacity values at standard ULT (-60/45 C), LT (-35/45 C), MT (-10/45 C), and HT (-5/45 C) conditions are listed in the table above for each refrigerant.

What is the cooling capacity of the BOCK HGX34e/315-4?

Running on R22, the BOCK HGX34e/315-4 delivers 3.41 kW at LT, 13.33 kW at MT, 16.41 kW at HT. Use the Benchmark tool to evaluate capacity at your exact SST/SDT and superheat conditions.

What type of compressor is the BOCK HGX34e/315-4?

DigiEntropy classifies the BOCK HGX34e/315-4 as FM_HG. Browse the BOCK catalog to compare nearby models from the same brand.

Can the BOCK HGX34e/315-4 be retrofit to a lower-GWP refrigerant under EU F-Gas Regulation 2024/573?

Open the F-Gas Retrofit tool with this model pre-selected to see drop-in alternatives ranked by capacity match, COP, GWP, PFAS impact, and 2026/2030/2035 phase-out timeline.

What polynomial standard is the BOCK HGX34e/315-4 performance data based on?

Capacity, power, and current polynomials follow EN 12900 for European-origin brands and AHRI 540 for North American brands. Coefficients are normalized into a common form for cross-brand comparison. Fit your own data in the Polynomial Fitter tool.