Danfoss A_R404A_HG22e125S

A

Danish hermetic scroll, reciprocating, and semi-hermetic screw compressors for commercial and industrial refrigeration.

Danfoss logo

Specifications

  • Compression technology: Reciprocating
  • Configuration: Single
  • Enclosure / drive: Semi-Hermetic
  • Variable speed: Not Stated
  • Hazardous-area certification: Not Stated
  • Product category: compressor

Qualified refrigerants & capacity

Calculated cooling capacity (kW). The evaporating / condensing temperature each column was evaluated at is listed per refrigerant, because the grid differs by refrigerant.

RefrigerantULTLTMTHTConditions
R404A1.35.496.76ULT -60 / 45 °C; LT -35 / 45 °C; MT -10 / 45 °C; HT -5 / 45 °C

Related Danfoss models

Frequently asked questions

What refrigerants does the Danfoss A_R404A_HG22e125S support?

The Danfoss A_R404A_HG22e125S is qualified for R404A. The table above lists capacity at ultra-low, low, medium and high temperature duty for each refrigerant, with the evaporating and condensing temperature each value was calculated at. Those conditions differ by refrigerant, so read them per row.

What is the cooling capacity of the Danfoss A_R404A_HG22e125S?

Running on R404A, the Danfoss A_R404A_HG22e125S delivers 1.3 kW at LT (-35 / 45 °C), 5.49 kW at MT (-10 / 45 °C), 6.76 kW at HT (-5 / 45 °C). These are calculated cooling capacities at the rating basis the manufacturer declares with its data, not measured values. Use the Benchmark tool to evaluate capacity at your exact SST/SDT and superheat conditions.

What type of compressor is the Danfoss A_R404A_HG22e125S?

DigiEntropy classifies the Danfoss A_R404A_HG22e125S as A. Browse the Danfoss catalog to compare nearby models from the same brand.

Can the Danfoss A_R404A_HG22e125S be retrofit to a lower-GWP refrigerant under EU F-Gas Regulation 2024/573?

Open the F-Gas Retrofit tool with this model pre-selected to see drop-in alternatives ranked by capacity match, COP, GWP, PFAS impact, and 2026/2030/2035 phase-out timeline.

Where does the Danfoss A_R404A_HG22e125S performance data come from?

From Danfoss's own published performance data, evaluated at the suction and liquid conditions the manufacturer declares with it. Which rating standard the manufacturer certifies to (EN 12900 or AHRI 540) is not stated on this page; check the manufacturer's datasheet. Fit your own data in the Polynomial Fitter tool.